hayward blue essence troubleshooting

Please consider. "@type": "ImageObject",
Armstrong Human Resource Management 13th Edition Pdf, There is another switch located at 6 oclock called the stationary switch. Hi Joe, the Perflex DE filter has a few dozen flex tubes covered in a mesh fabric. Power going in, but power not coming out and therein lies the problem, which could just be a loose wire, broken wire or faulty resistor/capacitor/relay. I have this same Drive Error Message. Your pump should be connected to a bare copper wire, test it to see if there is any voltage detected in the bonding wire. Hopefully the GFI then holds. Im having an air leak problem with my pool. Hi Gail, overheating can be caused by the wrong wire size from breaker to motor, or loose wire connections, or over-voltage coming into motor, or lack of ventilation around the motor (mulch piled up, or big bushes close by, or placed in a box cover), but its can also be a fatal fault inside the motor. Cap is fine, so I lost. Hi Don, when its not an air leak, pump surging will then be an obstruction in the pipe, or filter, heater, check valve/filter valve/diverter valve, a bit of plastic usually (once I found a golf ball, in the skimmer pipe), that is pulled into a 90 or up against a port that is too small for the obstruction to pass. Yes, if not grounded correctly, the GFCI will trip. I have a pump that wants to stop pumping water after a few minutes the flow gets very low. The early revisions dont work with the TCELL5 or TCELL9. Hi David, these can sometimes be tricky to seal up, you are not alone. But not a dirty filter? What am I not doing? Do you know what the suggested torque is for the housing cap screws? When it shuts down, does the High Salt light come on? My salt was tested today at 3000 and everything else was perfect. Thank you. When I turned the pump on it is very loud and the pump is not moving water. thanks. The arrow should point in the same direction as the water flow. Hi, it is either an air leak (a non-issue if installed below water level), or the suction pipes are too small for the pump size, or the hose may be collapsing inward under pressure. Hi Pump flow rates are found on pump flow rate curves. Please. Could also be a clogged pump impeller, or a clog in the skimmer line. No loose wires or insect infestation. When you installed the new lateral assy, did the standpipe come all the way up to the top of the tank, and insert neatly into the bottom of the multiport valve? On attempting to open the pool, the motor started humming. Once I get it going, it works fine for as long as I leave it on. The same thing happened to the first one. I removed the back of the pump and the yellow wire has a small black burn hole in it. We just opened our pool up cleaned everything out put new D.E. Hi Sean, the Powerflo pump lid has a very tight seal, likely the o-ring needs to be removed, cleaned off with a rag, replaced and lubed with a Teflon lubricant like Magic lube or other Pool Lube. If valve is open when it should be closed the heater will shut down and go into lockout. "keywords": "hayward pool pump",
Hello, Please note: The majority of our literature and brochures are in English only. Fourth, bad capacitor on the motor? Why does this keep happening? }
. The salt level is 2300 ppm or less and no chlorine is generating. As I started to prep for this season, I did notice that the positive and negative electrical terminals on the 3 prong cord were corroded and loose. Hose them off well, and then soak them in a DE filter cleaner, in a 5 gallon bucket. Call Hayward and speak to their tech support people, for more precise advice. Roger, I call that surging, when the pump catches prime, loses prime, catches again it can be a stuck skimmer weir or a pool noodle blocking water flow into the skimmer. 2 yrs is unusual for bearings to go. Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. Thanks! For the priming problem, you may have an air leak on the pump lid or around the pipe coming into the pump. On your filter (X-Stream and Voyager) there are two large wing nuts under the lid which secure the pressure gauge and air bleeder. Or if pump was off for some time, it can leak water, where it leaks air, when on. The Filter Design Flow Rate is usually printed on the label, or can be found online. I can turn the temperature up but not down. This issue started immediately after I changed the filter grids on my FNS plus 60 filter. Step 3: When the instant salt level is stable (and the negative sign still present), cycle slide switch to 'Super Chlorinate' and back to 'Auto'. The electrician also installed w new capacitors on the pump and still same problem. Thank you so much, Within the underground world of Japan, and the world at large, a certain man is known as the Evil Emperor. I dont see that code listed. The water flow coming out of the returns looks normal. Why would the pump and Polaris stop working at the same time? },
If you have an automatic controller, it could be a rickety relay or something. I just want to clarify..we had a problem with the fuse box and its just been changed. When I (electrician) arrived I was able to measure 38volts to ground in the water when the main pump (Hayward Tristar) is running. Make sure there is no water in the conduit from the timer to the pump, and breaker to timer. },
14mm Magnetic Spark Plug Socket, However, I havent tried to spin the shaft. For the green water, drop the pH to 7.2 and add enough shock until the water turns blue-ish, and run the filter 24/7. My pump motor does not start until I spin the shaft then it runs for about 15 min and shuts off and I can hear the motor humming and it feels very hot to the touch. Any thoughts? Hi Javi the capacitor on the motor may have failed. well, possibly it just needs to dry out. It does this everyday and then starts working like normaly for the rest of the day. goes on first, then the spring, then the slightly larger hole washer. Grab it and see if it looks/feels loose. Any thoughts? Water level is good, pipe connections are sealed and I checked I rings which seem fineI cant seem to figure out what is wrong. I have an sp3400vsp pump. Seems to take away the point of getting a variable speed pump if we have to run it on high all the time. 2) loose pipe coming into the pump (no sealant, or overheated and slightly shrunk), 3) Loose valve lids or o-rings, air-leaky valves in front of the pump (main drain, skimmer). Everything is Primed and ready to go, soon as I put the vacuumin on the skimmer, the pressure stays for about 30 secs then the pressure and water level drop to next to nothing. (The factory default is 2800 ppm). put in a new motor and had the old motor repaired. Thanks. Pool pump already went out a few months ago. Buen suerte! Do you think its the capacitor and I can get another one from Hayward, or possibly mis-wiring? Maybe sand it down briefly and WD-40 it after it comes off. Next, check continuity from lead to lead. Hayward pumps use different shaft seals, you can find the correct one here: https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG . I checked pool water supply and dont feel any water coming but my pump is still running but nothing is moving in pool. If your new pump is the exact same make/model/horsepower as the old pump, then the pump is not the problem but if you switched make/models check the pump flow curve, because even though it may be the same hp, different make/model pool pumps produce Vastly different flow rates. Likely not a problem with the pump itself. The hot side goes into the timer's N0-3 and common into com-1. News Reporter Reveals On Live TV That Shes Been Secretly Recording . Hi, my Hayward super pump is thermo protected. Otherwise it runs all the time or if you try to turn it on/off daily, but youre bound to be unavailable or maybe forget from time to time, I have a super pump and a salt water pool. how to watch past broadcasts on twitch. It can also be a bad outlet, and if older than 20 yrs, it could be the breaker too. Hope that helps! It worked fine just prior to a filter cleaning. Hi Scott, if the cracked case seal has any possibility of letting water in, maybe you can silicone it to seal it up. IF its a broken off grease cap, tap in a sharp screwdriver into where it threads in, to get some bite, and then slowly and firmly back out the broken off threaded connector, turning CCW, then replace with a new Grease Cap, or a 1/8 threaded plug. Hi Michael, common problem, which can be caused by a variety of issues, in order of possibility Hi Chris, is the vacuum hose fully primed with water before you attach it to the skimmer, you say primed and ready to go, so I assume so. presto, all working good! Anything else to fiddle with or bad motor? Hi Jimmy, no it need not have a controller, or a timeclock, it could just have an on/off (light type) switch. It got very wet and tripped the breaker. If it makes no noise at all, that is often a loose wire or no power. If you have power there, and the motor is making no sound then I would inspect closely for a loose wire on the terminal board, or a loose switch in the back, or loose capacitor wire. This happens even when the filter and skimmer basket is clean. Terrible storms 2 nights ago. When they fail, they often crack, bulge, leak or smell bad, but not always. "height": "219",
Running at low rpm seems to be fine. filter. Getting ready to start up my pool , flipped the breaker and nothing. Does the LED light turn off after 60 seconds? If the wrong o-ring size was used, that could cause the problem. Weve had our Hayward for four years now never had any problems.tonight my husband vacuumed the pool then back washed it. 8. check power at the motor, with a multimeter set on 240V+ place test probes on the brass screws or terminals where the two power wires connect. When tablets are used in the skimmers, Flex pipe beneath the skimmer can swell inside and begin to crimp and close (over many years time), so that a small amount of debris can clog the line. Hi Tom, if it is the same exact pump and pump size, that would be unusual, but if its the same horsepower, but a different pump model, that would be the simplest answer. The help at the pool store had no idea what could be wrong. 1.5 hayward pool pump motor clicks on and off rapidy. The most common areas for an air leak are the pump lid (is it as tight as possible? Shouldnt be having a problem so soon, no but it can happen, but more likely to not be the shaft seal, but the exit pipe, or a leak around the impeller housing, check the bolts around the pump, to be sure they are tight. "headline": "Hayward Pool Pump Troubleshooting",
http://www.inyopools.com/blogSHOP at our online store! the 4th wire, the high speed wire. Rust can develop inside the motor that you can break free, by spinning the shaft a few times. (PUMP and RETURN pipes). I would inspect it for corrosion, wire tightness, water damage or insect damage. Please tell me if this is normal or do I need to change anything? We have cleaned it 3-5 times a day and changed the d.e as well. Most Common areas include the pump lid (must be very tight, with lubed lid o-ring), and the threaded pipe that comes into the FRONT of the pump (must be very tight and sealed if loose, use Pool Putty to fix, or replace the fitting) the effluent or exit pipe fitting leaking will not draw air, that is on the pressure side not the suction side. Tighten in a Pattern (tighten up the bolts in a N, S, E, W, or 12, 6, 9, 3 pattern). My Hayward xstream filter pump is not turning on at all. If the gears are moving, then power should be coming out of the timeclock to the motor. Maybe not a pump issue, but supply issue. The best way to attack this is with the mantra the problem lies where the power dies. My diffuser does not tightly fit into my seal plate. If it is not a clog, it could be a collapsed skimmer line or drain line, if flex pipe was used underground on these lines. Thanks, Steve DeGray. Is it plug and play? The breakers still seem to be working since when I turn the breaker on and the timer switch for the pump, it does send power to the pump.